A1000 for Special Applications

A1000 Positioning Software

Precise positioning without an external position controller, rotary and linear
Integrated brake controls

Possible Digital Input Functions:

  • Position Selection
  • Reference Switch
  • Positive and Negative Over-Travel Switch
  • Disable Motion Control Switch
  • Manual / Positioning Mode Selection
  • Move / Reference Search Start Command Switch


Possible Digital Output Functions:

  • During Torque Limit
  • In-Position Signal
  • Brake Release Signal
  • Reference Search Ready Signal
  • Zone Signal
  • Output Contactor Control

Technical Details

Ratings 3 ~ 200V .... 240V +10%/-15%, 0.55kW - 110kW
3 ~ 380V .... 480V +10%/-15%, 0.55kW - 630kW
Max. Motor Output (kW) 3~200 VAC, 0.4 – 110
3~400 VAC, 0.4 – 630
Applicable Motor Induction Motor (IM)
Synchronous Motor (PM)
Control V/f Control
Open Loop Vector (OLV)
Closed Loop Vector (CLV)
Open Loop Vector (OLV) for PM
Adv. Open Loop Vector (OLV) for PM
Closed Loop Vector (CLV) for PM
Speed control range V/f and V/F with PG 1:40
OLV 1:200
CLV 1:1500
CLV and OLV for PM 1:1500*3
Torque Control Standard
Max. Output Frequency 400 Hz
Fieldbus Interfaces RS-232C
RS-422/485 (Memobus/Modbus)
MECHATROLINK-I
MECHATROLINK-II
Ethernet/IP
EtherCAT
Modbus TCP
PROFINET
CC-Link
DeviceNet
PROFIBUS-DP
CANopen
Standards CE
UL/cUL
RoHS
UL508C
EN ISO 13849-1 PLd
IEC/EN61508 SIL2
Enclosure IP00, IP20, IP54, NEMA1
Functions Speed/Torque Control Switching
Energy Saving Function
Double Rating (ND/HD)
Speed Search
Slip Compensation
Torque Compensation
PID Control (with sleep function)
Momentary Power Loss Ride-Thru
Application Parameter Presets
Preventive Maintenance Functions
RS-232C Interface
USB Interface